Project Description

  • BNA IR Stent
  • BNA IR Stent
  • BNA IR Stent

Biliary IR Metal Stents

BNA – Uncovered Stent

Indication: Indicated for the palliation of malignant strictures in the common bile duct

  • HYBRID WEAVE STRUCTURE – Lower returning force to allow the stent to better conform to the shape of the lumen

  • THICKER NITINOL WIRE THAN OTHER LEADING STENTS – Quicker expansion and more balanced radial force to maintain luminal patency in tortuous anatomy

  • ROUNDER EDGES – Minimises the risk of mucosal trauma

  • 9 RADIO-OPAQUE GOLD MARKINGS – Excellent visualisation under fluoroscopic guidance

Product Code Stent (mm) Delivery Device Box Size
Usable Length Total Length Diameters Length (cm) Diameter (mm/Fr)
BNA10060-H060 46 60 13.5-10-13.5 60 2.66 / 8 1
BNA10080-H060 66 80 13.5-10.13.5 60 2.66 / 8 1
Master Catalogue
  • SHS Metal STent

SHS – Uncovered Stent

Indication: For application in palliative treatment of biliary stricture, typically caused by malignant tumours

Product Code Stent (mm) Delivery Device Box Size
Usable Length Total Length Diameters Length (cm) Diameter (mm/Fr)
SHS-10-060-060 46 60 13.5-10-13.5 60 2.33 / 7 1
SHS-10-080-060 66 80 13.5-10.13.5 60 2.33 / 7 1
SHS-10-100-060 86 100 13.5-10.13.5 60 2.33 / 7 1
Master Catalogue
  • Benefit Stent
  • Benefit Stent

BNHS – Uncovered Stent

Indication: The non-covered Benefit™ Biliary Stent is used for application in palliative treatment of bile duct stricture caused by malignant tumours

Product Code Stent (mm) Delivery Device Box Size
Usable Length Total Length Diameters Length (cm) Diameter (mm/Fr)
BNHS-08-100-060 86 100 8-8-8 60 1.98 / 5.9 1
BNHS-08-120-060 106 120 8-8-8 60 1.98 / 5.9 1
Master Catalogue
  • BNY MEtal Stent
  • BNY Metal Stent
  • BNY Metal Stent

BNY – Uncovered Stent

Indication: For application in palliative treatment of biliary strictures and/or Klatskin-type malignant tumours

Product Code Stent (mm) Delivery Device Box Size
Usable Length Total Length Diameters Length (cm) Diameter (mm/Fr)
BNY-10-060-060 46 60 13.5-10-13.5 60 2.33 / 7 1
BNY-10-080-060 66 80 13.5-10.13.5 60 2.33 / 7 1
Master Catalogue
  • BCG Metal Stents
  • BCG Metal Stents

BCG – Fully Covered Stent

Indication: For the application in palliative treatment of biliary stricture and/or closure of perforations and post-surgical leaks and fistula by malignant or benign tumours

Product Code Stent (mm) Delivery Device Box Size
Usable Length Total Length Diameters Length (cm) Diameter (mm/Fr)
BCG-10-060-060 40 60 10-10-10 60 2.83 / 8.5 1
BCG-10-080-060 60 80 10-10-10 60 2.83 / 8.5 1
BCG-10-100-060 80 100 10-10-10 60 2.83 / 8.5 1
Master Catalogue

REQUEST A PRODUCT TRIAL

Please fill out the form below to organise your product trial or training. 